Reference Guide
B-19
TS 16 cannot be used with v&s.
You cannot assign a voice circuit with signaling to time slot 16 of an E1 WAN port.
TS 16 is already in use.
You cannot assign time slot 16 of a CEPT E1 WAN port programmed for cas.
TS Connection must be specified.
You must specify a time slot connection for the WAN circuit.
TS(s) cannot be allocated.
You cannot assign a voice cross-connect to time slot 16 of a CEPT E1 WAN port.
Unit controlled by FEC.
The user card is controlled by forward error correction.
Units in pair must have the same source.
You must configure the Source parameter of User units on a FRAD card in pairs.
Voice CPU is not responding.
The voice CPU is not working. Power down the system, then power it up again.
WAN must be active (no loopback) to run BERT test.
You must turn off all WAN loopbacks before starting a BERT test on a WAN port.
WAN must have SLC format.
The WAN port must be configured for slc96.
Xconnect table can be accessed from primary WAN.
You cannot access the WAN cross-connect information from a redundant WAN port. Do this
from a primary WAN port instead.